Changes in impedance of Ni electrodes upon standing and cycling
Read Online
Share

Changes in impedance of Ni electrodes upon standing and cycling by Margaret A. Reid

  • 54 Want to read
  • ·
  • 74 Currently reading

Published by National Aeronautics and Space Administration, For sale by the National Technical Information Service in [Washington, DC], [Springfield, Va .
Written in

Subjects:

  • Electrodes, Nickel.,
  • Nickel-cadmium batteries.,
  • Impedance (Electricity)

Book details:

Edition Notes

Distributed to depository libraries in microfiche.

StatementMargaret A. Reid.
SeriesNASA technical memorandum -- 102438.
ContributionsUnited States. National Aeronautics and Space Administration.
The Physical Object
FormatMicroform
Pagination1 v.
ID Numbers
Open LibraryOL15277990M

Download Changes in impedance of Ni electrodes upon standing and cycling

PDF EPUB FB2 MOBI RTF

EIS is particularly suitable for studying the reaction kinetics of electrodes and batteries. Many impedance studies have been carried out on lead/acid 1, 2, 3, Ni/Cd 4, 5, 6, Zn/MnO 2, Na/S, and Ni/H 2 batteries. Only a few previous EIS studies on metal hydride electrodes and Ni/MH batteries have been by: Changes in impedance of Ni/Cd cells with voltage and cycle life [microform] / Margaret A. Reid Changes in impedance of Ni electrodes upon standing and cycling [microform] / Margaret A. Reid Explore. Changes in impedance of Ni electrodes upon standing and cycling [microform] / Margaret A. Reid Characterization of cobalt-dipped nickel electrodes with Fibrex substrates [microform] / Carolyn A. Youn. The reason for low impedance is because a high impedance input would be in parallel with the source impedance of the skin (typically about K). The signal will find the path of least resistance.

Porous zinc electrodes are elaborated, assembled in Zn/Ni 3–4 Ah prismatic batteries and monitored upon charge/discharge cycling ( cycles at C/3 rate followed by cycles at 1C rate). Migration of zinc within the thickness of the zinc electrodes is revealed by X-Ray radiography, scanning electron microscopy, and X-EDS elemental by: This is not true of metal electrodes. This reversibility requires a soluble chloride containing electrolyte gel or paste such as Ten20 EEG paste. Because the sintered silver/silver chloride electrodes are thermodynamically reversible, they exhibit low noise and theoretically zero electrode polarization impedance effects.   This website and its content is subject to our Terms and Conditions. Tes Global Ltd is registered in England (Company No ) with its registered office 5/5(2). Abstract. Electrical Impedance Tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area, and boundary shape under the electrode).File Size: KB.

An EKG measures the amount of voltage and the _____ it takes for the voltage to travel throughout the heart time In the application of the electrodes, secure the electrode by .   This website and its content is subject to our Terms and Conditions. Tes Global Ltd is registered in England (Company No ) with its registered office . The MIEC in the composite electrodes forms a porous, 3-dimensional heterostructure providing good electrochem. contact upon cycling as indicated by SEM and electrochem. impedance spectroscopy. The sulfur in the S-MIEC composite retains a capacity of > mA Cited by: The solid electrolyte interphase (SEI) forms during the initial cycles in lithium ion batteries and evolves throughout the battery life. By protecting the electrode and passing lithium ions, the SEI plays an important role in the performance and degradation of lithium ion batteries. Identifying how the SEI forms and evolves during battery cycling helps us understand and mitigate battery Cited by: